Basic Info.
Application
Highway, Square, Garden
Product Description
1, Scope of application:The intelligent lighting time control module is applicable to residential quarters, residential landscape lights, schools, libraries, villas, machine rooms, market markets, shopping malls, supermarkets, KTVs, public cultural and entertainment places, bus stations, high-speed railway stations, airport waiting for halls, hotels, schools, museums, banks, workshops, offices, warehouses, hospitals, fish pond breeding Areas or industries such as electric equipment that are inconvenient for human operation and places requiring intelligent control of electric equipment, but they are not suitable for flammable, explosive and highly corrosive environments.
2, Product features2.1 the intelligent lighting time control module (hereinafter referred to as the module) can carry out intelligent power on and power off control for lighting or other loads DC / AC 0-220V equipment. The load power controlled by this product shall not exceed 500W. If the load equipment power exceeds the rated power, it is necessary to connect the AC contactor at the output end of the module control circuit, and the module switch controls the coil of the contractor to ensure the service life of the module.
2.2. Each circuit of the module can be set with a variety of control scenarios: independent timing, manual control, intelligent panel remote control, 4-section timing switch control, astronomical latitude and longitude control, remote light sensing, temperature sensing (LCD only), computer background, mobile phone app control, etc.
2.3 the module provides a 24V fire emergency interface and fire feedback function. When there is a fire signal input, the module can automatically open or close all circuits and switch to the emergency state, so as to facilitate the timely protection of personnel and property and prevent or reduce economic losses.
2.4.86 the intelligent panel can remotely open, close, fully open, and close the module.
3, Basic functions3.1. The intelligent time control module has an independent timing function for each loop;
3.2. It can start the longitude and latitude time control function, and enable the automatic light on/off time at dawn and dark according to the different longitude and latitude of each region (longitude and latitude can also be set freely);
3.3. Light control and temperature control functions (only for liquid crystal type);
3.4. Fire linkage function: 24V signal is input externally to enable full open or full close (fire circuit is set to fully open and non-fire circuit is set to full close);
3.5 digital and LCD display, man-machine friendly interface;
3.6. Support can and RS485 communication. The default can communication, other communication modes are required, which shall be explained when ordering;
3.7. 4 sets of time period settings for each circuit;
3.8, Support astronomical clock and festival/holiday scene mode (LCD only);
3.9 fire control feedback function.
4, Main technical parametersPerformance / category | Nixie tube display module | LCD module |
working voltage | AC 220V±10% | AC 220V±10% |
load current | ≤20A | ≤20A |
power waste | 8W | 8W |
Control action time | ≤0.5S | ≤0.5S |
Fire input | DC 24V | DC 24V |
control loop | 4,8,12 | 4,8,12 |
ambient temperature | -20~+60ºC | -20~+60ºC |
ambient humidity | 10%~90% | 10%~90% |
Communication mode | CAN RS485 , wireless GPRS | CAN RS485 , wireless GPRS |
5, Installation instructionsIn order to ensure that the module is in good working condition, please read the instructions correctly and install it correctly. Before installation, carefully check whether the equipment model, parameters, overall dimensions and instructions correspond to the real object. If they are verified to be correct, install according to the requirements and conditions. Do not operate blindly.
Product name | Installation mode | remarks |
Intelligent lighting time control module | 35mm standard guide rail | Usually installed in the distribution cabinet |
5.2 installation dimension: unit: mmSpecifications | Length (L) | wide (W) | Height (H) |
4-way module | 108 | 95 | 64 |
8-way module | 179 | 95 | 64 |
12 channel module | 251 | 95 | 64 |
6, Key description of digital display time control module6.1. The "set" key is used for the entry port when setting parameters;
6.2 double function "OK / save" key is used to enter the selected page and long press to save parameters.
6.3. Double function "full on / full off, up / down" key, long press the full on or full key to turn on or off all switches. It is used for front shift or rear shift when setting parameters.
6.4. Dual function "+ / -, single on / single off" keys are used for numerical addition and subtraction setting, loop addition and subtraction selection and single on or single off operation;
7, Setting and operation of digital display moduleSet category | Function coding | Operating instructions |
Basic parameters: year, month, day, hour, minute and address | P0001 | Under the time division interface (main interface), press the setting key. When the nixie tube displays p0001, press the OK key to enter. Press the "scroll down" key to set the time division and IP address in turn. After setting, long press the "save" key until "-" appears on the interface, and the parameters are saved successfully |
Under the time division interface (main interface), press the setting key. When the nixie tube displays p0001, press the OK key to enter. Press the "scroll down" key to set the time division and IP address in turn. After setting, long press the "save" key until "-" appears on the interface, and the parameters are saved successfully |
P0002 | Under the time division interface (main interface), press the "set" key, and then press the "scroll down" key. When the nixie tube displays p0002, press the "OK" key to enter the timing setting interface. Press the "+ / -" key to switch the circuit. When the indicator light of the selected circuit is on, press the "scroll down" key to display the number 1 flashing. Press the "scroll down" key to set the first lighting on time, and then press the "scroll down" Press the key to set the minute time, then press the "scroll down" key, the circuit indicator light is on, then press the "scroll down" key, the period 1 is flashing, then press the "+" key to select 2 is flashing, then press the "scroll down" key to set the first section of light off time, and then press the "scroll down" key to set the minute time. In this way, 1 on, 2 off, 3 on, 4 off, 5 on, 6 off, 7 on, 8 off, and then press the "save" key for a long time until "-----" appears on the interface The parameters are saved successfully, so that the four time periods of the first circuit are set, and then press the "+" key to select the next circuit and set the required time in turn.
|
Time control synchronization and fire fighting | P0003 | Under the time division interface (main interface), press the setting key, and then press the scroll down key. When the nixie tube displays p0003, press the OK key to enter the time control synchronization and fire linkage settings. The first 1 flashes for time control synchronization, which is set to 1 synchronization. The timing time of all circuits is consistent with that of the first circuit, which is set to "0" out of synchronization. After selection, press the "scroll down" key, and the fire linkage is set to full open 0 is all off. Press and hold the "save" key until "-" appears on the interface, and the parameters are saved successfully |
GPS enable settings | P0004 | Under the time division interface (main interface), press the "set" key, and then press the "scroll down" key. When the nixie tube displays p0004, press the "OK" key to enter the longitude and latitude setting. The first "0" indicates that it is not enabled, press the "+" key to change to "1" indicates that longitude and latitude are enabled, and long press the "save" key until "----" appears on the interface |
External passive signal input settings | P0005 | Under the time division interface (main interface), press the "set" key, and then press the "scroll down" key. When the nixie tube displays p0005, press the "OK" key to enter the two-way external signal input settings, press the "+ / -" key to switch the loop, and press the "scroll down" key to shift the switch. When the parameter flashes, press the "+ / -" key to set valid and invalid. Set to 1 enabled, set to 0 not enabled. Press and hold the save key until "----" appears on the interface, and the parameters are saved successfully |
Restore factory settings | P0006 | Under the time division interface (main interface), press the setting key, and then press the turn key. When the nixie tube displays p0006, press the OK key to restore the factory setting until "-" appears on the interface, and the parameters are saved successfully |
Full open and full close | / | Long press the full open or full key to turn on or off all switches |
Single billing and closing | / | Long press the setting key to enter the single opening and single closing setting interface. When the display "01" flashes, it represents the first switch. Press the flip key to select 1 as on and 0 as off, then press the flip key to select the circuit, and then press the "+ / -, single opening and single closing" keys for single opening or single closing operation. |
8, Setting and operation of LCD intelligent time control module8.1 key function description:
8.1.1 the "set" key is used for the entry port when setting parameters. Press the "+" key to enter the password "1000" to enter;
8.1.2 double function "OK, save" key is used to enter the selected page and long press to save parameters.
7.1.3 double function "full on / full off, up / down" key, long-press the full on or full key to turn on or off all switches. It is used for front shift or rear shift when setting parameters.
8.1.4 double function "+ / -, single on / single off" keys are used for numerical addition and subtraction sets, loop addition and subtraction selection and single on or single off operation. Under the main interface (year, day, week, address, light sense, temperature interface), press the turn key to enter the single-on and single offsetting interface. After entering, press the up and down keys to switch the circuit, and press the + / - key to single open or single close.
9, PrecautionsThe module is high-precision electronic equipment. It must be handled with care during transportation and unpacking without severe impact. It shall be transported and stored according to GB / t15464 general technical conditions for instrument packaging. The temperature of the storage place is 0 ºC ~ + 40 ºC, the relative humidity shall not exceed 85%, and there is no corrosive gas in the air.
Non-professional personnel is not allowed to install, operate and maintain the equipment.
The product is guaranteed for two years. Without the consent of the company, no person shall disassemble the product without authorization. If the product is disassembled without authorization of the company, we will be deemed to automatically give up the warranty service of the company.
10, After-sales serviceDear users, you are welcome to use our products. Within 18 months from the date of delivery, you will enjoy our warranty service. If you have any questions, please contact our after-sales service department, and we will serve you wholeheartedly. During this period, the user shall use, repair and maintain according to the specifications. If the product cannot be used normally due to product quality problems, the company is responsible for repair or replacement.
Address:
No. 19 Huancheng East Road, Liushi, Yueqing, Wenzhou, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Light Industry & Daily Use, Manufacturing & Processing Machinery, Security & Protection
Company Introduction:
Zhejiang Wangjia Electric Technology Co., Ltd. is a production-oriented and independent R & D manufacturer located in Wenzhou, Zhejiang Province. Established in 2012, as a factory, we can flexibly cooperate with customers′ time arrangement, output requirements, quality control, appearance requirements and provide OEM services. Complete production line, high matching production and technical cooperation are our greatest advantages. In addition, we can provide reasonable manufacturer prices to ensure 18 months of after-sales service and damage replacement service within a certain range. The company has always adhered to the concept of "people-oriented, attentive service", the pursuit of perfect quality and meeting customer requirements are our primary production objectives and the direction of our sustainable operation.
Our main products are: Electricity meters, water meters, electric energy meters, low-voltage components, including dual power automatic transfer switches, overvoltage and undervoltage protectors, control protection switches, fire power monitors, fire detectors, etc. We have more than 20 years of industry experience and more than 9 years of production experience. We have sales outlets all over the country, And there are cooperation cases with Southeast Asia, South America and other countries.
Give us a chance to understand and cooperate with each other.